Reliable model e alarm check valves are installed in either the vertical or horizontal position in the main supply to the wet pipe system. Eps101 and eps102 alarm pressure switches system sensor eps10 series switches are designed for use in wet, dry, deluge, and preaction automatic sprinkler. The impeller and drive shaft are energy efficient, made from light weight nonmetallic material and do not require any external lubrication. Firelock alarm check valve series 751 victaulic free. Alarm valve is a double seated clapper check valve with grooved seat design, which ensures positive water flow for alarm operation and is designed for installation in wet pipe sprinkler system. Deluge valves are used in conditions that require for quick application of large volumes of water and, for that reason, are often integral components in fire protection systems. System reset procedure for the viking wet pipe alarm check valve system. When water flows in the sprinkler system due to the operation of one or more automatic fire sprinklers the alarm valve opens, allowing continuous flow of water into the system and a transmission of an alarm, both electrically and mechanically. When there is a steady flow of water into the sprinkler system due to a sprin kler operation, the waterway clapper. Rapidrop model e wet alarm valves are designed for use in wet pipe sprinkler installations in buildings not subject to freezing temperatures. Clavals fire protection check valves are available in an array of configurations to fit any fire suppression system.
The pressure gauge on the system side of the alarm check valve clapper should indicate water pressure equal to or greater than the water pressure indicated on the gauge located on the supply side of the clapper. A range of reliable fire sprinkler control valves ex stock. Residential fire sprinklers for plumbing officials rob neale, vice president national fire service activities icc pmg membership council october 18, 2016 provide plumbing officials the ability to evaluate the important aspects of residential fire sprinkler systems. Valve automatically shuts off the water supply when a leak is detected automatic monthly maintenance cycling of the valve to ensure reliable operation valve can be opened and closed with the touch of a button activates an audible alarm when a leak is detected. Alarm check valve grooved x grooved and flanged x grooved product description the victaulic series 751 alarm check valve works as a check valve by preventing the reverse flow of water from the system piping to the water supply. The reliable model e alarm check valve acts as a water flow. Variable pressure with closed retard drain model e1 retard chamber is required. Wet systems use automatic sprinkler heads attached to piping containing water and connected to a water supply. Connect ps10 into alarm port piping that extends from the intermediate chamber of the alarm check valve. Alarm check valve shall be equipped with a water motoroperated mechanical alarm or pressure switch to initiate an electric alarm.
Alarm check valves shall be ul listed and fm approved. Reliable fire sprinkler control valves fire protection centre. Reliable alarm valves and associated trim must undergo periodic inspectiontesting. Alarm check valve offered by newage fire protection industries private limited, a leading supplier of check valves in sion, mumbai, maharashtra. The valve is designed to initiate an alarm during a sustained flow of water such as the flow required by an open sprinkler by operating an optional water. Designation wet alarm valve water supply main drain valve alarm test valve alarm shutoff valve 102317 bafsa b. Description alarm valve is a double seated clapper check valve with grooved seat design, which ensures positive water flow for alarm operation and is designed for installation in wet pipe sprinkler system. Infuvalve brochure reliable back check valve against fluid backflow during iv therapy.
Wet systems are the most common and reliable types of sprinkler systems. Must be from a reliable source municipal authority, privat e provider, or domestic. Bulletin 418 model e alarm check valve 212 and 65mm. Insure that no unsupervised shutoff valves are present between the alarm check valve and the ps10. Get indepth information on reliable automatic sprinklers e alarm valves including detailed technical specifications and product datasheets. The design allows for installation under both variable. The sprinkler alarm should not be located more than 1. If it aint broke, dont fix it the victaulic patent has run out and vision has picked up the great design and history of the vic 005h style rigid grooved coupling. Nov, 2014 this video describes the arrangement, operation and alarm testing of a wet sprinkler system that uses a riser check valve and water flow alarm.
Alarm valves are designed to initiate an alarm through water motor gong bell andor pressure switch during a sustained flow of. Inspect the check valve clapper located on the bypass line. Retard chamber shall be a single cast iron body, one gallon capacity, and rated for a working pressure of 175 psi. This valve is generally installed between the siamese connections and the riser to prevent backflow. Spring is completely removed from fl ow path closed as the inlet supply pressure decreases, a light spring closes the poppet, positioning the knifeedge automatically in line of contact sealing against the oring. Accomplished by opening the water bypass test valve. Hd alarm valves act as a check valves by trapping pressurized water above the clapper and preventing reverse flow from sprinkler piping. Victaulic series 751 firelock alarm check valve alarm. It does sound a continuous alarm when the sprinkler system operates.
What is a tamper switch for fire protection systems. Residential fire sprinklers for plumbing officials rob neale, vice president national fire service activities. Variable pressure water supply requires the use of either of two model e3 variable pressure trim sets and a reliable model e1 retard chamber. It is most important to ensure a clean water supply free of debris and solid particles such as sand, gravel, or mud. The valve is designed to initiate an alarm during a sustained flow of water such as the flow required by an open sprinkler by operating an optional water motor alarm andor alarm. Instructions for 4 6 installation, operation, 200mm care. Inspection and testing is to be carried out only by an authorized person. During a sustained flow of water, such as the flow required by an open sprinkler, hinged clapper 9 moves off seat to the open po sition. Once the alarm check valves are activated, they will allow water to flow through the system, engaging the sprinkler system as and where needed in order to suppress a potential fire. Prevents the reverse flow of water from the system piping to the water supply. Install on the outlet side of the inline check valve of the alarm port piping.
Globe alarm check valve installation and maintenance guide page i table of contents april 2004 bulletin a. Alarm check valve 4100 mm, 6150 mm, 8200 mm sizes with model e3 trim. Any alarm check valve should be carefully tested, examined, and cleaned periodically in accordance with nfpa 25. Reliable driptight shutoff utilizes a threeway solenoid to open or close the valve. Alarm valve is a double seated clapper check valve with grooved seat design, which ensures positive water flow for alarm operation. Verify that the appropriate trim chart and technical data for the alarm check valve and associated equipment are. This is one of two typical riser configurations for. The reliable model e and model e3 alarm check valve acts as a water flow alarm device in wet pipe sprinkler systems. Two model e3 high pressure trim sets are available for use with the model e3 high pressure alarm valve. Model j1 alarm check valve the viking model j1 alarm check valve serves as a check valve by trapping pressurized water above the clapper and preventing reverse flow from sprinkler piping. Instructions for installation, operation, care and maintenance. We provide a complete range of fire products for onestop solution to optimize customers demand and lower customers cost, including fire sprinkler system, fire hydrant system, fire alarm system, and fire suppression system. Tpmc is a reliable supplier of comprehensive fire system solution around the world. Alarm pressure switch the series 751 firelock alarm check valve is designed to allow the installation of pressure switches to activate electric alarms and control panels when a sustained flow of.
The reliable model e alarm check valve acts as a water flow alarm device in wet pipe sprinkler systems. Check valve x43hl hstrainer flow flow claval 750b4kg1 pressure relief valve claval. The valve is spring actuated and has a grooved end. Alarm valves must undergo functional testing, cleaning, inspection and if necessary, replacement of parts once a year as a minimum. Where water pressure fluctuates, such as encountered with city water supplies, variable pressure trim including an excess pressure pump or a retard chamber must be used. The e3 trim sets for the reliable model e alarm valve fig. Product image for e alarm check valves with e3 trim. Fire protection solutions for onshore applications deluge pressure relief. The valve is trimmed with a water bypass line, which has an inline swing check valve. Once the pressures stabilize, the alarm check valve is in service and the centrally located groove in the seat ring is sealed. The reliable cast iron swing check valve is distributed by nibco. External bypass minimizes false alarms under all supply pressure conditions. B instructions for installation, operation, care and maintenance. Bulletin 417 january 2019 model e 4 100 mm, 6 150 mm.
Water flows through ports in grooved seat, and enters the alarm port to activate alarm devices connected to the system. The bypass check valve reduces the possibility of false alarms by permitting slow as well as small transient increases in water supply pressure to be passed through. Reliables alarm valve prevents a false alarm in these circumstances using two features. Check valves prevent backflow by automatically closing when fluid reverses direction. The bypass line allows pressure surges to enter the system without causing false alarms. Once activated, alarm check valves will allow water to flow through the sprinkler system, initiating the sprinklers to suppress a fire. The reliable model e alarm check valve acts as a water. Vds cea requires minimum periodic inspection, testing and maintenance. The trims also serve as a means for testing the operation of the alarm devices while exercising the alarm valve clapper. This video describes the arrangement, operation and alarm testing of a wet sprinkler system that uses a riser check valve and water flow alarm.
Clean the 20 nb 34 strainer provided on the sprinkler alarm bell line. E3 high pressure alarm check valve with e3 trim reliable sprinkler. Alarm check valve newage fire protection industries. Deluge valve working principle what is a deluge valve. Reliable s alarm valve prevents a false alarm in these circumstances using two features. At its basic core, a valve is going to help control water throughout a web standpipe system. One sprinkler alarm may be connected to one or maximum of three alarm lines of separate fire systems. Water motor alarm hydraulically operated mechanical sprinkler alarm model cv1fr riser check valv 2 through 8 model rm1 model rm1 riser manifold commercial and residential rapid response model rsv1 residential shutoff valve, dualpurpose water supply, domestic and fire sprinkler system model av0 model av0 alarm valve. The reliable range of fire sprinkler control valves has proven on site performance and their ease of installation ensures they remain a popular choice with fire sprinkler installers. The viking model j1 alarm check valve serves as a check valve by trapping pressurized water above the clapper and preventing reverse flow from sprinkler piping.
The trim also serves as means for testing the operation of the alarm devices without causing the system to operate. The company was incorporated in 1961 and is registered with indiamart. Deluge valve working principle instrumentation tools. Alarm pressure switch the series 751 firelock alarm check valve is designed to allow the installation of pressure switches to activate electric alarms and control panels when a sustained flow of water such as an open. Reliable e3 instructions for installation, operation care. Inspection and testing is to be carried out only by. For interconnecting more than one sprinkler alarm, a swing check valve in each line need to be provided. Not all products are registered and approved for sale in all countries or regions. Alarm check valve sprinkler systems our products home description alarm valve is a double seated clapper check valve with grooved seat design, which ensures positive water flow for alarm operation and is designed for installation in wet pipe sprinkler system. Open the alarm shutoff valve in the alarm valve trim, and verify that all other valves are in their normal operating position.
An effective technical precaution to raise safety to complex infusion systems. If, during the annual inspection of alarm check valves, sediment or free particles of matter are noted, a further. Retard chamber shall be ul listed and fm approved and used with the globe model h series alarm check valves in systems have fluctuating water supplies, which could result in false alarms. Victaulic series 751 firelock alarm check valve alarm devices. This is because no equipment other than the sprinkler heads are required to operate.
Fire sprinkler system alarm check valves victaulic. The tamper switch is on the lookout for a closing butterfly valve and signals the control panel when it happens. Designation wet alarm valve water supply main drain valve alarm test valve alarm shutoff valve 102317 bafsa. Alarm valve is a double seated clapper check valve with grooved seat design, which ensures positive water flow for alarm operation and is designed for. This type of system does not have an alarm check valve. Alarm valves, designed to initiate an alarm through water. Reliable automatic sprinklers e alarm alarm check valve. The av0 alarm check valve trim includes pressure gauges to monitor system pressure conditions, a bypass check valve, a main drain valve, and an alarm test valve. Close the alarm test valve and verify that water has ceased to flow from the alarm line drain.
External bypass prevents false alarm under all supply pressure condition. There are different valves used in automatic sprinkler systems, such as check valves, alarm valves, and drain valves. The spring holds the valve clapper closed, so that water will flow only in one direction. Alarm check valve fireguard safety equipment co ltd.
Claval check valves fire protection products claval. Sprinkler system control valve inspection testing and. This type of wet alarm valve is designed to automatically initiate electric or hydraulic alarm whenever there is a flow of water to one or more sprinklers. Globe alarm check valve installation and maintenance guide table of contents june 2016 page i bulletin a. Excess pressure pump trim option available upon request. The astra 4alarm valve model e must be installed vertically in the main supply to a wet type sprinkler system. Shield sprinkler alarm is a hydraulically driven mechanical bell. Viking wet pipe alarm check valve system system reset. The alarm check valve is a small device consisting of a spring, valve clapper and alarm port. Product image for e3 high pressure alarm check valve with e3 trim.